High Frequency Variable Frequency AC Power Supply
$900-8000 /Piece/Pieces
Payment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Min. Order: | 1 Piece/Pieces |
Transportation: | Ocean,Land,Air |
Port: | SHANGHAI,NANJING,QINGDAO |
$900-8000 /Piece/Pieces
Payment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Min. Order: | 1 Piece/Pieces |
Transportation: | Ocean,Land,Air |
Port: | SHANGHAI,NANJING,QINGDAO |
Model No.: VFP - H
Brand: IDEALTEKNIC
Place Of Origin: China
Output Power: ≫500w
Input Voltage: Single Phase 220vac / Three Phase 380vac
Input Frequency: 50/60hz
Working Principle: Pwm
Power Supply Type: Igbt-Based
Working Mode: Constant Voltage / Constant Current
Display Mode: Digital Led
Control Mode: Knobs & Buttons
Protections: Ovp, Ocp, Otp And Short Circuit Protections Etc.
Applications: Ac Motor Test / Home Appliance Test
Cooling: Forced Air Cooling
Selling Units | : | Piece/Pieces |
Package Type | : | Plywood case |
Picture Example | : | |
Download | : |
VFP-H Series High Frequency AC Power Supply
Overview
High Frequency AC Power Supplies convert AC electric to pure sine waveform by through AC – DC – AC conversion, which is different from variable frequency speed controller and common AC voltage regulator.
AC Power Supplies are mainly used to convert existing AC power network supply to stable and pure sine power supply with regulated required frequency. The features of ideal AC Power Sources are stable frequency, stable voltage, zero internal resistance and Sine wave form (without distortion).
High Frequency AC Power Sources are close to the ideal AC Power Supplies , so the developed countries more frequently use Variable Frequency Power Supplies as the standard supply to provide the most excellent powering environment for electrical equipment and to easily evaluate their technical performance. Major types of Variable Frequency AC Power Supplies are: Linear Amplification and PWM Switching.
VFP-H series High Frequency AC Sources are manufactured under SPWM mode; it is designed by MOSFET module as active component, and adopts other technologies as digital frequency division, D/A conversion, instantaneous feedback and sinusoidal pulse width modulation to make the capacity of single unit up to 150KVA. Isolated transformer used to enhance total stability, strong load applicability, high quality output waveform, and simple operation, small size and light weight. In addition, this power supply has many protective functions against short circuit, over current, over load and over heat to ensure proper operation.
Comparing to traditional frequency inverter power supplies, our inverter power supplies remove the transformer and frequency converter, by using pure high-frequency conversion technology, with built-in by AC/DC and DC/AC parts, our AC High Frequency Power Supplies could give stable AC output with prefect output precision.
Because, our new technology does not need transformer for conversion and isolation, the power supplies' size can be reduced within the same output power rating, and not limited by the transformer, output frequency could reach 15 ~ 1Khz continuously adjustable.
Features
l Isolated output; reliable and convenient operation.
l No high and low level limit, output voltage continuously adjustable in the full scope.
l Wider output frequency scope, 15Hz ~ 1KHz continuous adjustable, could withstand continuously working within full output frequency scope.
l Pure high-frequency inverter technology, AC/DC,DC/AC module architecture.
l High total efficiency.
l Good output voltage & frequency stability.
l Output button plus Shuttle knob control.
l LCD Display.
l RS232 serial port for remote control, MODBUS-RTU communication protocol.
l Complete protection functions.
l Small size, light weight.
Installation Environment
l Ambient temperature: Please have the power source working in safe temperature range (0℃ ~ 45℃) or it would affect life of power source.
l Please install the power source at least 50cm distant from surroundings to have better ventilation.
l Please install the power source away from vibration (less than 0.6G), especially equipment like puncher.
l Keep the power source away from direct sunshine, humidity or place with water globule.
l Keep the power source from corrosive, flammable & explosive gas.
l Keep the power source away from oil stain, dust & metallic dust.
Specifications |
||||
Model |
Single-phase Three-phase |
|||
Output capacity |
500VA ~ 600KVA |
|||
Circuit mode |
SPWM mode |
|||
AC Input |
Phase |
Single-phase / Three-phase |
||
Voltage |
220Vac ± 10% / 380Vac ± 10% / 480Vac ± 10% |
|||
Frequency |
50Hz, 60Hz ± 5% |
|||
AC Output |
Phase |
Single-phase / Three-phase |
||
Voltage |
0 ~ rated output voltage value 110V / 120V / 220V (static points) |
|||
Frequency |
50Hz / 60Hz (static points) 15 ~ 1000Hz (custom output frequency range) |
|||
Max. current |
Depends on output capacity |
|||
Control mode |
Local |
Button + Shuttle knob |
||
Remote |
RS485 communication interface. In line with MODBUS-RTU standard. |
|||
Output waveform |
Pure sine wave |
|||
Frequency stability |
≤0.1% |
|||
Load regulation |
≤±0.5% (resistive load) |
|||
Line regulation |
≤±0.5% (resistive load) |
|||
Harmonic distortion |
≤1.5% (115V 400Hz) ≤3% (115V 15 ~ 400Hz) ≤4% (115V 400Hz ~ 1000Hz) |
|||
Efficiency |
≥85% (80% ~ 100% loading) |
|||
Output display |
LCD |
|||
Display resolution |
Frequency Meter |
0.1Hz, accuracy: ±0.3%FS |
||
Voltage Meter |
0.1V, accuracy: ±0.3%FS |
|||
Current Meter |
0.1A, accuracy: ±0.3%FS |
|||
Power Meter |
0.01KW, accuracy: ±0.3%FS |
|||
Protections |
Auto tripping and alarm when over voltage, over
load, over temp, over current and short-circuit. |
|||
Cooling mode |
Forced air-cooling type |
|||
Working Environment |
Relative humidity |
0°C ~ 40°C |
||
Working temperature |
0-90% (non-condensing) |
|||
Height |
≤1500m |
|||
Size (W*H*D) (mm) |
287*98*320(500VA ~ 1000VA) 440*132*600(3KVA) Other Depend on output capacity |
|||
Weight (Kg) |
Depends on output capacity |
l Airdrome ground establishment, radar, ship, spaceflight, and military electronic manufacturing & debugging.
l Other situations which need variable high frequency (15Hz ~ 1000Hz).l 0 ~ 5V / 0 ~ 10V / 4 ~ 20mA analog signal control. (DB port) (+AC)
l RS communication interface (RS232 / RS485 optional) (+RC)
l USB port (+USB)l Check whether the bolts or moisture loosen regularly.
l Check whether water leakage at pipe connection regularly.
l Check whether any leaking of water pipe connection regularly.
l Regularly open the box side plate, cleaning dust inside.
l Regularly with clip-on ammeter check three-phase input current that it is abnormal and serious drift phenomenon, if abnormal, contact the supplier in time.
l Specially assigned person for equipment maintenance.Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.