High Precision High Voltage Capacitor Charging Power Supply
Get Latest PricePayment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Min. Order: | 1 Piece/Pieces |
Transportation: | Ocean,Land,Air,Express |
Port: | SHANGHAI,NANJING,QINGDAO |
Payment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Min. Order: | 1 Piece/Pieces |
Transportation: | Ocean,Land,Air,Express |
Port: | SHANGHAI,NANJING,QINGDAO |
Model No.: CCP - 6U
Brand: IDEALTEKNIC
Place Of Origin: China
Output Power: ≫500w
Input Voltage: Three Phase 380vac
Input Frequency: 50/60hz
Working Principle: Pwm
Power Supply Type: Igbt-Based
Working Mode: Constant Voltage / Constant Current
Display Mode: Digital Led
Control Mode: 10-Turn Potentiometers
Protections: Ocp, Short Circuit And Load Discharging Protections Etc., Ocp, Short Circuit And Load Dischargin
Applications: Lab Test / Hipot / Capacitor Charging
Circuit Mode: Pwm
Output Voltage Range: 1 Kv ~ 100 Kv
Output Current Range: 60 Ma ~ 6000 Ma
Output Type: Single
Cooling: Forced Air Cooling
Selling Units | : | Piece/Pieces |
Package Type | : | Plywood case |
Picture Example | : | |
Download | : |
CCP Series High voltage Capacitor Charging DC Power Supply
Overview
The CCP-6U series High Voltage Power Supplies expands and upgrades the output capacity on the basis of the CCP-4U High Voltage Capacitor Charging Power Supplies. It adopts a 19-inch 6U standard rack-mount chassis, the output power can reach 6KW, and the output voltage level is 1KV / 2KV / 3KV / 4KV / 5KV / 6KV / 8KV / 10KV / 12KV / 15KV / 20KV / 30KV / 40KV / 50KV / 60KV / 70KV / 80KV / 100KV, this series of High-voltage Capacitor Charging Power Supplies expands the output voltage and power range on the basis of maintaining high efficiency, high output response speed and faster protection start self-recovery features.
The output voltage and current of the HV Capacitor Charging Power Supplies can be controlled and read through the front control panel. And, this series of Capacitor Charging High Voltage Power Supplies are also equipped with a DB50 interface as standard. Customers can edit the control software according to our communication protocol or apply 0 - 10V signal and dry contact signal on the interface according to our interface definition to achieve control and monitoring of the Capacitor Charging HVPS, such as high voltage start/stop, output settings and readings.
With complete protection functions, the HV Capacitor Charger can deal with overvoltage, overcurrent, load discharge and other situations.
Features
l Can be used as a HV DC power supply or as HV capacitor charging power supply.
l Output voltage adjustable from 0 to 100%
l Output power: Average charging @ 3KJ/S and the peak charging power can reach 3KW.
l Charging in constant current mode and switch to constant current mode till fully charged.
l Unique double isolated system, strong anti-interference ability.
l Forced air cooling, very rugged design.
Applications
l Ion beam implantation.
l Semiconductor process.
l Electron beam welding.
l Capacitor charging.
l High-power RF transmitter.
l Electrostatic precipitator.
l X-ray system.
1. This power module has HV output, only professional person could operate it.
2. Please make sure of good grounding before operation.
3. Capacitor charging power supply has low internal stored energy, please NO no-loading working.
4. Keep power module clean and good ventilation.
5. HV input & output connectors or HV load no touch anything.
Note: All the models have basic complectation including input line, HV line, GND line, interface lines...etc
Input |
Voltage |
Three-phase 380Vac (input tolerance: 10%) |
|
Frequency |
50Hz/60Hz |
||
Connection |
Input line provided by iDealTek. (1.5 meters) |
||
Output |
Rated power |
3KW ~ 6KW (Max.) available ** |
|
Output voltage adjusting range |
1KV / 2KV / 3KV / 4KV / 5KV / 6KV / 8KV / 10KV / 12KV / 15KV / 20KV / 30KV / 40KV / 50KV / 60KV / 70KV / 80KV / 100KV available ** (For other output voltages, please contact us for details) |
||
Output current adjusting range |
0A ~ ****mA |
||
Output polarity |
Positive or Negative (both available) Client must choose one output polarity before ordering. |
||
Line regulation |
≤0.1% for ±10% change in input voltage. |
||
Load regulation |
≤0.1% for no load to full load at output. |
||
Ripple (Vr.m.s.) |
≤0.1% @ rated output. |
||
Output connection |
Detachable shielded high-voltage cable provided by IdealTek. (3 meters) |
||
Efficiency |
≥90% |
||
Setting & Display |
Output control mode |
Local |
10-turn potentiometer on front panel. |
Remote |
DB50 analog port & RS485 communication port. |
||
Display mode |
Display mode |
41/2 LED digital display |
|
Display resolution |
≤1% (range: 5%~100% of the rated value) |
||
Protection & Monitoring functions |
Load discharging protection |
When the load has discharging due to insufficient safety distance between load and ground, the power supply shutdown the high voltage output, and then restarts, so cycle like this till the discharging fault is eliminated. |
|
Short circuit protection |
When a short circuit occurs between the load and the ground, the power supply works in constant current mode, the current is limited to the maximum value, and the voltage drops to 0 to protect the internal inverter from damage. |
||
Over current protection |
When the users' load exceeds the rated load and cause over-loading, the power supply works in constant current mode, the power supply output current does not change, and output voltage decreases. |
||
Noise |
≤65dB |
||
Protection degree |
IP20 |
||
Cooling method |
Forced air cooling (Front inlet, rear outlet) |
||
Working environment conditions |
Ambient temperature |
0℃~40℃ |
|
Humidity |
10%~90% (non-condensing) |
||
Height |
≤2000m |
||
Storage environment conditions |
Ambient temperature |
-20℃~60℃ |
|
Humidity |
10%~90%(non-condensing) |
||
Height |
≤2000m |
||
Size (W*H*D) (mm) |
483*266*573 (19” sub-rack 6U chassis) |
||
Weight |
45KG (1KV ~ 10KV) 55KG (20KV ~ 100KV) |
||
|
Front panel description |
||
|
||
No. |
Description |
|
1 |
Power Switch (POWER) |
|
2 |
HV ON / OFF Switch (HV) |
|
3 |
Local / Remote Switch (LOCAL / REMOTE) |
|
4 |
Analog / RS communication Switch |
|
5 |
HV adjusting knob |
|
6 |
Current adjusting knob |
|
7 |
HV output display |
|
8 |
Output current display |
|
9 |
Emergency Button |
|
10 |
Reset switch |
|
Front Panel Indicator Lights Description |
||
|
||
Indicator lights name |
Description |
|
POWER ON |
After the CONTROL POWER switch is set to the ON position, the light becomes on, indicating that the power input has been connected and the power supply is normal. |
|
HV ON |
After the HV switch is set to the ON position, the light becomes on, indicating that the high-voltage output of the power supply is started and the power supply is normal. |
|
CONST HV
|
When the light is on, it indicates that the power supply is working in a constant voltage state. |
|
CONST mA |
When the light is on, it indicates that the power supply is working in a constant current state. |
|
CONST POW |
When the light is on, it indicates that the power supply is working in a constant power state. |
|
OVER VOLTAGE |
When the light is on, it indicates that the power supply has a high voltage overvoltage fault. |
|
INV OVERI |
This light is on, indicating that the power supply has an inverter overcurrent fault. |
|
INV OVER TEMP |
This light is on, indicating that the power supply has an inverter over-temperature fault. |
|
HV OVER TEMP |
When the light is on, it indicates that the power supply has an over-temperature fault with the high-voltage part. |
|
SPARK EXCEEDED |
When the light is on, it indicates that the power supply has a discharge fault. |
|
AC FAULT |
When the light is on, it indicates that there is an AC fault (overvoltage or under voltage) fault in the power supply. |
|
EMERGENCY |
When the light is on, it indicates that the power supply is in an emergency stop state with faults. |
|
INTERLOCK |
When the light is on, it indicates that the power supply is in an interlocked state and the power supply is normal. |
|
Rear panel description |
||
|
||
Mark |
Description |
|
E1 |
Grounding bolt |
|
J1 |
HV output interface |
|
JB1 |
DB50 control interface |
|
CB1 |
Main power switch |
|
LINE INPUT |
Power Supply input interface Three – phase, four – wire (L1 è Black, L2 è Red, L3 è Grey, Null è Blue, PE è Green) |
|
AIR EXHAUST |
Cooling fans |
KV |
mA |
P (KW) |
Model |
KV |
mA |
P (KW) |
Model |
1 |
6000 |
6 |
CCP-(N/P)6kW-1kV |
15 |
400 |
6 |
CCP-(N/P)6kW-15kV |
2 |
3000 |
6 |
CCP-(N/P)6kW-2kV |
20 |
300 |
6 |
CCP-(N/P)6kW-20kV |
3 |
2000 |
6 |
CCP-(N/P)6kW-3kV |
30 |
200 |
6 |
CCP-(N/P)6kW-30kV |
4 |
1500 |
6 |
CCP-(N/P)6kW-4kV |
40 |
150 |
6 |
CCP-(N/P)6kW-40kV |
5 |
1200 |
6 |
CCP-(N/P)6kW-5kV |
50 |
120 |
6 |
CCP-(N/P)6kW-50kV |
6 |
1000 |
6 |
CCP-(N/P)6kW-6kV |
60 |
100 |
6 |
CCP-(N/P)6kW-60kV |
8 |
750 |
6 |
CCP-(N/P)6kW-8kV |
70 |
86 |
6 |
CCP-(N/P)6kW-70kV |
10 |
600 |
6 |
CCP-(N/P)6kW-10kV |
80 |
75 |
6 |
CCP-(N/P)6kW-80kV |
12 |
500 |
6 |
CCP-(N/P)6kW-12kV |
100 |
60 |
6 |
CCP-(N/P)6kW-100kV |
|
l 0 ~ 10V analog signal control (DB50 interface)
l RS communication interface (RS485 communication port)
Drawings (for reference only) |
6U chassis ((2KW) (RAL7035) |
|
|
|
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.