ADPS Series Programmable Capacitor Ripple Current Endurance Test Power Supply
Overview
ADPS series Programmable Capacitor Ripple Current Test Power Supply could give mixed output of high-frequency AC output and regulated DC output, with built-in power amplifier powered by Tracking DC Source, it could give 1KHz ~ 100KHz high-frequency AC output, which could meet the special test needs of high-frequency, high-current passive components test needs, such as high-frequency capacitors, film capacitors, electrolytic capacitors, stabilizer capacitors and stabilizer inductance etc.
User could set working frequency and voltage as per characteristic of DUT.
And, thanks to its built-in MCU, its output parameters are programmable; it has many kinds of programming functions, such as timing preset output, multiple group parameter call and sequence output programming etc. which could meet different needs of different test programming.
Features
l Pure sine wave output, low waveform distortion, good output waveform.
l Voltage, current, frequency continuously adjustable in full scale.
l Has automatic storage function, could store 10 groups of setting parameters.
l Has the waveform programming output function, frequency, voltage, current, and holding time of output waveform are all programmable, and the maximum setting is 999 cycles.
l Timing preset function, can set the output running time, the maximum running time is 999H.
l Touch screen gives convenient visual operation interface to customer.
l Constant voltage, Constant current working modes, two working modes are automatic switchable as per load conditions.
l Digital control adopted to give higher output accuracy and better output stability.
l RS485 remote control port for output control & monitoring.
l Programmable output function.
l High-frequency isolation output for safer operation.
l Modular redundancy design, more convenient maintenance.
Programmable Functions
The power supply has the parameter programmable function, through the parameter value and output mode programming.
The programmable parameters are as follows:
(1). Voltage parameter: Output voltage value, voltage rising time, voltage working holding time and voltage descending time.
(2). Current parameters: Output current value, current rising time, current working holding time, and current descending time.
(3). Frequency parameter: Output frequency value, frequency rising time, frequency working holding time and frequency descending time.
(4). Cycle: Number of cycles.
Specifications
Output mode | Dual-output with neutral point | |||
Rated power | 10KW | |||
Input | Connection mode | Three – phase, four – wire + GND | ||
Voltage | 380V±10% | |||
Frequency | 50Hz/60Hz±5Hz | |||
Output | DC Output | Working mode | CV / CC | |
Output voltage adjusting range | 0.0V ~ 600.0V | |||
Output current adjusting range | 0.000A ~ 3.000A | |||
Output voltage precision | ≤0.5%FS+0.5 | |||
Output current precision | ≤0.5%FS+0.5 | |||
Line regulation | ≤0.1%FS | |||
Load regulation | ≤0.2%FS | |||
Temperature drift | ≤0.03%/℃ | |||
Time drift | ≤0.3%FS | |||
Ripple (Vr.m.s.) | ≤0.5% F.S (measured @ rated voltage with 80%-100% resistive loading) | |||
AC Output | Output waveform | Sine waveform | ||
Working mode | CV / CC | |||
Output voltage adjusting range | 0.00V-50.00V (continuously adjustable) | |||
Output current adjusting range | 0.0A-80.0A (continuously adjustable) | |||
Output frequency adjusting range | 5KHz ~ 100KHz | |||
Output voltage precision | ≤0.5%+0.5FS | |||
Output current precision | ≤0.5%+0.5FS | |||
Output frequency precision | ≤0.1% | |||
Harmonic (THD) | ≤3% (measured@50V output voltage) | |||
Line regulation | ≤0.1%FS | |||
Load regulation | ≤0.2%FS | |||
Temperature drift | ≤0.03%/℃ | |||
Time drift | ≤0.3%FS | |||
Setting & Display | Control mode | Local | Front panel LCD touch screen. | |
Remote | RS485 communication interface. In line with MODBUS-RTU standard. | |||
Display mode | LCD touch screen | |||
Set & Display error | DC Voltage | 0.1V | ||
DC Current | 0.001A | |||
AC Voltage | 0.01V | |||
AC Current | 0.01A | |||
AC Frequency | 0.01KHz | |||
Programming function | Parameter Store and calling | Supports 10 sets of parameters programmable and stored, and 10 sets of storage parameters can be called freely. | ||
Timing working | Working time scope: 0.1H-999.9H | |||
Output programming | AC voltage | Output voltage value, rising time, descending time, holding time. | ||
AC current | Output current value, rising time, descending time, holding time. | |||
AC frequency | Output frequency value, rising time, descending time, holding time. | |||
Cycle | 0-999 | |||
Protection & Monitoring functions | Input protection | Input lack voltage and lack phase protection. | ||
Output over voltage protection (OVP) | Output over voltage protection value settable. Power supply automatically cuts off output and alarms when output has over voltage. | |||
Output over current protection (OCP) | Output over current protection value settable. Power supply automatically cuts off output and alarms when the output has over current. | |||
Over temperature protection (OTP) | Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds 85 °C. | |||
Output short-circuit protection | Power supply automatically cuts off output and alarms when the output has short-circuit. | |||
Load characteristic | Applicable to capacitive load, inductive load and mixed type load. | |||
Noise | ≤65dB | |||
Protection degree | IP21 | |||
Cooling method | Forced air cooling | |||
Safety features | Insulation resistance | ≥20MΩ | ||
Withstand voltage ability | 60s test @ 2000VDC, no flash-over or spark-over. | |||
Grounding inductance resistance | ≤100mΩ | |||
Working conditions | Ambient temperature | 0℃~45℃ | ||
Humidity | 10%~90%(non-condensing) | |||
Height | ≤2000m | |||
Size (W*H*D) (mm) | 600*1500*800 |
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.