Robust High Power High Voltage Power Supply
Get Latest PricePayment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Min. Order: | 1 Piece/Pieces |
Transportation: | Ocean,Land,Air,Express |
Port: | SHANGHAI,NANJING,QINGDAO |
Payment Type: | T/T |
Incoterm: | FOB,CFR,CIF,EXW |
Min. Order: | 1 Piece/Pieces |
Transportation: | Ocean,Land,Air,Express |
Port: | SHANGHAI,NANJING,QINGDAO |
Model No.: HPS
Brand: IDEALTEKNIC
Place Of Origin: China
Input Voltage: Three Phase 380vac
Input Frequency: 50/60hz
Working Principle: Pwm
Power Supply Type: Igbt-Based
Working Mode: Constant Voltage / Constant Current
Display Mode: Digital Led
Control Mode: 10-Turn Potentometers
Protections: Ovp, Ocp, Otp, Short Circuit And Load Discharing Protections.
Applications: Capacitor Charging, Electro-Gun, 3d Printing, Electrostatic, Ion Injection.
Cooling: Forced Air Cooling
Selling Units | : | Piece/Pieces |
Package Type | : | Plywood case |
Picture Example | : | |
Download | : |
HPS Series High Power High Voltage DC Power Supply
Overview
HPS series ultra High-Power High-voltage Power Supplies are developed on the basis of HP series High Power High-voltage Power Supplies using internal high-power high-voltage modules in parallel, using 19-inch standard cabinet, control part, inverter, and high-voltage transformer are installed in side under split design.
This series of High Voltage Power Supplies are featured for ultra-high accuracy, high precision, and high stability electronic characteristic. The output voltage is optional from 5KV to 300KV, and the power has reached an astonishing ultra-wide range of 50KW to 500KW. The power supply adopts a mixed cooling method of air cooling of the control part, water cooling and oil cooling of the main power unit. The internal module redundancy technology and perfect protection circuit ensure the excellent reliability of the high voltage Power Supplies under high-voltage and high-power output.
This series of high-power High-voltage Power Supplies uses touch screens with built-in potentiometers and The LCD meter or LCD for high voltage output control and monitoring. This series of High Power HV Power Supplies can be equipped with RS485 interface and control software to control and monitor the operating parameters of the high-voltage power supply
This type of High-Power HV Power Supplies are currently mainly customized according to cleints' requirements, and the industries currently involved are cutting-edge industries such as mining gravel, super-power capacitor charging, electron beam smelting, and tube aging.
Features
l Short circuit protection Could accept long-term discharge sparking and short-circuiting for special-purpose environments also can be made to be short-circuit protection. High-voltage power supply is equipped with a special output current short-circuit suppression circuit to prevent high-voltage power supply output discharging and sparking short circuit The high-voltage power supply is equipped with a special discharging protection circuit to ensure that other equipment and the power supply are not damaged. Ultra-short protection time: When the sensitive current detection circuit detects that the current exceeds the protection set value, power supply would enable the current-limit & power-limit circuit to ensure that the output current is controlled within the set value. The protection startup time is within 10 microseconds and can be achieved in 3 microseconds as requirements. l Double current-protection circuit The first-level protection: The dynamic current detection control circuit stabilizes the current at the set value dynamically. The second-level protection: when the output current threshold protection control circuit detects that the output current exceeds the set threshold value, power supply immediately stops the current energy output cycle, and re-enters the next energy output cycle when the circuit resets, and the control circuit has soft-start process on new energy cycle after each reset, that is, the energy output has a rising process from zero to maximum. This control mode ensures a smooth process for each energy output. The power supply voltage-drop flash detection circuit detects short-circuit and sparking condition of the load at the first time, and enables the protection circuit in time. l Redundancy technology HPS high-power power system has redundancy configuration inside, this design can cut off any one or a group of single-unit at any time without interrupting the operation of the entire power supply system. The application of this technology improves the stability of some systems that cannot be powered down. l Module design The power system adopts modular design, the front-end inverter and the rear-stage rectification are independent of each other, which makes installation and maintenance easy. l Overvoltage protection When the output voltage exceeds the upper limit voltage set by the customer, the power supply will automatically cut off the output and alarms. l Overcurrent protection Over current protection value 0 ~ 100% rated value continuously adjustable, power supply activates protection when current exceeds protection value. l Overload protection Power supply has built-in overload protection circuit to prevent the power supply from being damaged due to overload. l Overheat protection Power supply has built-in over-heat protection circuit, power supply activates protection when the temperature of the power supply radiator exceeds 75 degrees and the automatically resumes below 75 degrees. l Grid input protection Power supply shutdown when the input voltage exceeds the range of 342V ~ 420V. l Constant voltage (CV) & Constant current (CC) Output voltage & current continuously adjustable from 0 to rated value, CV & CC automatically switchable. l Linkage adjustment The latest linkage adjustment technology, using a network cable to connect each module via synchronous adjustment of each module to achieve the average output of each module. l Surge limit
Safety Cautions
1. This power module has HV output, only professional person could operate it.
2. Please make sure of good grounding before operation.
3. Capacitor charging power supply has low internal stored energy, please NO no-loading working.
4. Keep power module clean and good ventilation.
5. HV input & output connectors or HV load no touch anything.
Key technology |
l The HPS high voltage power supply adopts the multi-module series & parallel connection technology to balance the output of each module. l The HPS high voltage power supply adopts optical fiber isolation sampling technology. l The HPS high voltage power supply adopts the temperature control system to control the cooling fan speed. This cooling control mode reduces both unnecessary energy consumption and fan noise while extending fan life. l The HPS high-voltage power supply adopts small built-in HV oil tank and modular layout structure, the high-voltage components are immersed in oil for heat dissipation, which effectively reduces the temperature of high-voltage power components and greatly extends the service life of insulating materials. l The high voltage transformer in the oil tank adopts double high voltage insulation mode. l The heat pipe technology is adopted to achieve better dissipation of the heat sink, lower local temperature of the power components, and greatly extends the service life of power components. |
Block diagram |
|
Input |
Connection mode |
Three-phase, four-wire (PE), TN-S supply mode. |
|
Voltage |
380Vac (input tolerance: 10%) |
||
Frequency |
50Hz/60Hz±10% |
||
Current |
Depends on output power rating |
||
Output |
Rated power |
****KW (Max.) |
|
Output voltage adjusting range |
0 ~ ***KV |
||
Output current adjusting range |
0A ~ *****mA |
||
Output polarity |
Positive or Negative (both available) Client must choose one output polarity before ordering. |
||
Working mode |
Constant voltage (CV) / Constant current (CC) |
||
Accuracy (C.V.) |
Line regulation |
≤0.2% FS (Output voltage change rate only caused by changes of input voltage over a specified range of variation) |
|
Load regulation |
≤0.2% FS (Output voltage change rate only caused by full range load changes) |
||
Accuracy (C.C.) |
Line regulation |
≤0.2% FS (Output current change rate only caused by changes of input voltage over a specified range of variation) |
|
Load regulation |
≤0.2% FS (Output current change rate only caused by full range load changes) |
||
Ripple (r.m.s) |
≤0.3% FS (measured @ 80% ~ 100% rated output) |
||
Output connection |
HV connector and line provided by IdealTek. |
||
Power factor |
cosΦ= 0.92 |
||
Efficiency |
≥90% (measured @ 80% ~ 100% resistive load) |
||
Working ability |
Withstand long-term continuous working at full load. |
||
Setting & Display |
Output control mode |
Voltage & Current continuously adjustable via 10-turn potentiometer or touch screen with self-locking function. (Depends on output power rating) |
|
Display mode |
41/2 LCD digital display or LCD (Depends on output power rating) |
||
Display error |
≤±0.5%FS ± 1digit (range: 50%~100% of the rated value) |
||
Display resolution |
As per output voltage & current values. |
||
Protection & Monitoring functions |
Input protection |
Input lack phase protection. |
|
Over voltage protection (OVP) |
Power supply automatically cuts off output and alarms when output has over voltage. |
||
Over current protection (OCP) |
When the users' load exceeds the rated load and cause over-loading, the power supply works in constant current mode, the power supply output current does not change, and output voltage decreases. |
||
Over temperature protection (OTP) |
Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds its threshold value. |
||
Short circuit protection |
When a short circuit occurs between the load and the ground, the power supply works in constant current mode, the current is limited to the maximum value, and the voltage drops to 0 to protect the internal inverter from damage. |
||
Inverter transient protection response time |
≤10us |
||
Start-up overshoot |
No start-up overshoots. |
||
Over-loading capacity |
Withstand working with 1.05 times of rated current. |
||
Short protection mode |
CC working when short-circuit. |
||
Noise |
≤65 ~ 75dB |
||
Protection degree |
IP20 |
||
Cooling method |
Forced air cooling / Oil-immersed cooling / Oil-immersed cooling + Water cooling + air cooling HV oil tank: oil-immersed cooling Rectifier & Inverter part: water cooling (external water injection required) Other parts: Forced air-cooling. Direction: The lower part of the left and right sides - In and Top - Out wind |
||
Working environment conditions |
Ambient temperature |
-10℃~40℃ |
|
Humidity |
10%~80%(non-condensing) No conductive dust, gas or steam that destroys the insulating medium No severe vibration and shock, good ventilation. |
||
Height |
≤2000m |
||
Storage environment conditions |
Ambient temperature |
-20℃~60℃ |
|
Humidity |
10%~80%(non-condensing) |
||
Height |
≤2000m |
||
Size (W*H*D) (mm) |
19” cabinet with 1000mm / 1200mm / 1800mm Height (Depends on output power rating) |
||
Weight |
Depends on output power rating |
||
|
KV |
mA |
P (KW) |
Model |
|||
50 |
1000 |
50 |
HPS-(N/P)50KW-50KV |
|||
100 |
500 |
50 |
HPS-(N/P)50KW-100KV |
|||
200 |
250 |
50 |
HPS-(N/P)50KW-200KV |
|||
50 |
2000 |
100 |
HPS-(N/P)100KW-50KV |
|||
100 |
1000 |
100 |
HPS-(N/P)100KW-100KV |
|||
150 |
667 |
100 |
HPS-(N/P)100KW-150KV |
|||
200 |
500 |
100 |
HPS-(N/P)100KW-200KV |
|||
50 |
3000 |
150 |
HPS-(N/P)150KW-50KV |
|||
100 |
1500 |
150 |
HPS-(N/P)150KW-100KV |
|||
150 |
1000 |
150 |
HPS-(N/P)150KW-150KV |
|||
200 |
750 |
150 |
HPS-(N/P)150KW-200KV |
|||
100 |
2000 |
200 |
HPS-(N/P)200KW-100KV |
|||
200 |
1000 |
200 |
HPS-(N/P)200KW-200KV |
|||
150 |
2000 |
300 |
HPS-(N/P)300KW-150KV |
|||
300 |
1000 |
300 |
HPS-(N/P)300KW-300KV |
|||
More models are coming
soon.
l 0 ~ 5V / 0 ~ 10V / 4 ~ 20mA analog signal control. (DB port) (+AC)
l RS communication interface (RS232 / RS485 optional) (+RC)
19-inch Industrial-grade
Cabinet (RAL7035 / BLACK)
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
|